Which Waste Exemptions Are Most Common?

The seven below, of about 60, grouped as U (using waste), T (treating), D (disposing) and S (storing). Each has an Environment Agency guide listing its waste codes (find one with our EWC code finder). Whether you need one, registering and what it costs: waste exemptions.

These are today's limits. England plans to change all seven from 2027, if Parliament approves: what changes.

U1: Using Waste in Construction

U1 lets you use suitable waste in building, engineering, drainage and landscaping work: a noise bund of crushed brick and concrete, a track built from road planings, or imported soil for landscaping as part of a construction project. Over its 3 years you can use up to 5,000 tonnes of wastes such as concrete, bricks and aggregates, up to 1,000 tonnes of soil and stones, or up to 50,000 tonnes for a road built to an engineering standard with a sealed surface. Waste can be stored for up to 12 months before use.

It must be suitable for the job and not contaminated with things like plastic, asbestos fragments or oil. U1 doesn't cover standalone landscaping, land levelling or land reclamation, or treating waste to make it suitable.

How Do I Register a U1 Exemption?

In England, the business using the waste registers it in its own name through the Environment Agency's online waste exemption service, with the details under Registering in England. U1 is band 1: £435.96, plus the £58.13 registration charge, for 3 years. In Wales you register with Natural Resources Wales, free.

T4: Preparing Waste for Recycling

T4 covers treatment that reduces volume before waste goes elsewhere for reuse or recycling: baling paper and cardboard, baling and shredding cans, sorting plastic bottles. Limits depend on the waste. For paper and cardboard, you can treat up to 500 tonnes outside or 3,000 tonnes indoors in any 7 days, and store up to 15,000 tonnes, for up to 12 months.

Each waste type must arrive separately and be kept apart. You can't treat hazardous waste or bale waste going to landfill or incineration. If you only bale waste where it is produced, you don't need to register.

T6: Chipping Waste Wood and Plant Matter

T6 covers chipping, shredding, cutting or pulverising waste wood and plant matter to make it suitable for a use such as mulch, panel board, fuel or path surfacing. You can treat or store up to 500 tonnes over any 7 days, and store the treated material for up to 3 months.

It doesn't cover hazardous treated wood, sorting wood out of mixed waste, or wood sorted from mixed sources at a waste treatment facility.

T9: Recovering Scrap Metal

T9 covers sorting, grading, baling, crushing, shearing by manual feed or cutting scrap metal with hand-held tools. You can store or treat up to 1,000 tonnes at any one time (50 tonnes of cable), for up to 24 months, on sealed drainage. Keep records of each load's quantity, nature and origin for 2 years.

T9 doesn't allow end-of-life vehicles or their parts, hazardous waste, or burning. In England, T9 is due to end on 6 April 2027, when a scrap metal site will need a permit instead (what to do).

S2: Storing Waste at a Secure Place

S2 lets you store certain wastes at a secure site away from where they were produced, until they move on for recovery elsewhere. Each waste has its own limit: for example, 15,000 tonnes of paper and cardboard for 12 months, 15,000 tonnes of scrap metal for 6 months, 100 tonnes of non-hazardous construction and demolition waste that can be reused as it is, or 40 tonnes of tyres for 3 months.

You can't treat waste under S2, store waste going for disposal, store mixed waste, or mix hazardous with non-hazardous waste.

D7: Burning Plant and Untreated Wood Waste

D7 lets a business such as a gardener, joiner or farmer burn its own untreated wood and plant waste in the open, where it was produced. You can burn up to 10 tonnes in any 24 hours and store up to 20 tonnes for up to 6 months to dry it.

You can't bring waste in from elsewhere to burn. Householders burning their own garden waste don't need to register.

U16: Parts from Depolluted Vehicles

U16 lets a business such as a repairer or classic car restorer reuse parts from end-of-life vehicles in other vehicles. You can hold up to 2 depolluted vehicles and 5 cubic metres of their non-hazardous parts at a time.

The vehicles must have been depolluted at an authorised treatment facility, and kept somewhere secure on an impermeable surface. You can't remove parts to sell to other people. In England, U16 is due to end on 6 April 2027, like T9.

Check the Official Guidance

Sources: The 11 Official Pages This Guide Is Based On

How TIPPA Helps

  • Your exemption checked on its regulator's register, with the waste codes each one allows.
  • Its storage limits counted as loads come in, with a warning as you near one. Reporting add-on
  • A warning 30 days before it expires, and its renewal put in its place.
  • Customers' exemptions checked, and printed on their transfer notes.

Free for life. Pay only for the extras you choose.